ISO 13485Sector-specific standardsEdition 2016
ISO 13485: Medical Devices Quality Management System
Quality requirements for medical device manufacturers and suppliers, focused on safety and regulatory requirements.
On this page
What is ISO 13485
ISO 13485 is the international standard that sets out the requirements for a quality management system (QMS) for organizations involved with medical devices. Its title states its purpose: these are requirements for regulatory purposes. The standard helps organizations consistently provide safe and effective products that meet both customer needs and the requirements of health authorities.
Although it originated from ISO 9001, ISO 13485 is a standalone standard with its own priorities. It places more weight on documentation, risk management, process validation and compliance with regulatory requirements than on customer satisfaction in a broad sense. That is why ISO 13485 certification is a recognized reference in the healthcare sector in many countries.
Which organizations is it for
The standard applies to organizations involved in one or more stages of the life cycle of a medical device:
- manufacturers of equipment, instruments, implants, single-use products and in vitro diagnostic devices;
- companies that design and develop devices, including software that qualifies as a medical device;
- importers and distributors that store and deliver these products;
- installation, maintenance and servicing companies;
- suppliers of components, raw materials and critical services, such as sterilization, calibration and packaging.
Key benefits
- A basis for regulatory compliance: the requirements of the standard align with the good manufacturing practice requirements adopted by health authorities in many countries.
- Patient safety: risks are assessed and controlled throughout the product life cycle.
- Validated and traceable processes: critical activities, such as sterilization and packaging sealing, have proven performance, and products can be traced when necessary.
- Fast response to problems: complaints, adverse events and field actions are handled through defined procedures.
- Credibility with customers and partners: hospitals, manufacturers and distributors often require certification when qualifying suppliers.
Structure and main requirements
ISO 13485 has its own structure, closer to earlier versions of ISO 9001 than to the common structure used by most management system standards. Its most distinctive requirements are:
- Regulatory requirements at the core: the organization identifies its role with the authorities, such as manufacturer, importer or distributor, and builds the requirements that apply in the markets where it operates into the system.
- Product documentation: for each type or family of device, a medical device file is kept with specifications, manufacturing, packaging, labeling, installation and servicing instructions.
- Risk management: apply a risk-based approach to the processes of the system and manage product risks throughout product realization, usually based on ISO 14971.
- Design and development: planning, inputs and outputs, reviews, verification, validation, including clinical or performance evaluation when required, and change control.
- Purchasing and suppliers: evaluate and monitor suppliers according to the risk they pose to the product.
- Production and process validation: control product cleanliness, contamination, validation of special processes, identification and traceability, with additional requirements for implantable and sterile devices.
- Feedback and post-market activities: collect information from the market, handle complaints, report to regulatory authorities when required and implement corrective and preventive actions.
How the certification process works
- Regulatory mapping and gap analysis: the organization identifies its products, markets and applicable requirements and compares its current system with the standard.
- Implementation: medical device files, risk management, design controls, validations, post-market procedures, internal audits and management review are put in place.
- Stage 1 audit: the certification body reviews the documentation, the scope, the product classification and the readiness of the system.
- Stage 2 audit: auditors check design records, process validations, supplier controls, complaint handling and traceability in practice, by sampling products and batches.
- Certification and surveillance: once nonconformities are addressed, the certificate is issued for the activities and products assessed. Periodic audits maintain it until recertification.
Frequently asked questions
Does ISO 13485 certification replace regulatory approvals?
No. Market authorizations and good manufacturing practice certifications are granted by health authorities under their own rules. In Brazil, for example, good manufacturing practice certification for medical devices is issued by ANVISA. ISO 13485 certification is voluntary, although a QMS that conforms to the standard helps a great deal in meeting regulatory requirements.
What is the difference between ISO 13485 and ISO 9001?
ISO 9001 is generic and emphasizes customer satisfaction and continual improvement. ISO 13485 is specific to medical devices and focuses on product safety and effectiveness, documentation and compliance with regulatory requirements.
Can distributors and service providers get certified?
Yes. The standard allows certification of only the activities the organization actually performs, such as storage, distribution, sterilization or servicing, as long as exclusions are justified.
Can software developers get ISO 13485 certification?
Yes, when the software is a medical device or part of one. In this case, design and development controls and risk management become even more important.
Request a proposal
Want to certify your quality management system to ISO 13485? Contact DRV to request a proposal. We will learn about your products, activities and markets and propose an approach suited to the scope of certification.