ISO 50001Health, safety and environmentEdition 2018
ISO 50001: Energy Management System
Structures continual improvement of energy performance, cutting consumption, costs and related emissions.
On this page
What is ISO 50001
ISO 50001 is the international standard that sets out the requirements for an energy management system (EnMS). It guides organizations in using energy more efficiently, with an ongoing method to understand where and how energy is consumed, set targets, implement improvements and prove the results with data.
Unlike one-off efficiency projects, such as replacing lamps or motors, ISO 50001 creates a management routine that keeps energy on the organization’s agenda. A distinctive feature is that ISO 50001 certification requires a demonstrated improvement in energy performance, not just the existence of procedures.
Which organizations is it for
The standard can be applied by any organization, but it delivers the greatest return where energy weighs heavily on costs or emissions, such as:
- food, chemical, paper, ceramics, metals and mining industries;
- shopping centers, hospitals, hotels and large commercial buildings;
- data centers and operations with intensive cooling;
- water utilities and logistics companies with fleets or pumping systems;
- organizations with greenhouse gas reduction targets.
Key benefits
- Lower costs: using less energy to produce the same output cuts expenses on an ongoing basis.
- Lower emissions: energy efficiency contributes directly to climate targets and sustainability reports.
- Data-driven decisions: measurements and indicators show where to invest and what effect each action had.
- More efficient purchasing and design: energy performance is considered when buying equipment and designing facilities.
- Engaged teams: operators and technicians understand how their practices affect consumption.
Structure and main requirements
ISO 50001 follows the structure shared by management system standards and adds technical tools specific to energy management:
- Energy management team: top management appoints people with the authority and competence to run the system.
- Energy review: analyze energy sources, energy use and energy consumption based on measurement and data, and identify significant energy uses (SEUs), the variables that affect them and opportunities for improvement.
- Energy performance indicators (EnPIs): define suitable indicators to measure performance, such as consumption per unit produced or per conditioned area.
- Energy baseline (EnB): establish a quantitative reference, normalized for relevant variables such as production or weather, to compare performance over time.
- Objectives, targets and action plans: set improvement targets and the actions to achieve them, with deadlines and owners.
- Operational control, design and procurement: set operating and maintenance criteria for significant energy uses and consider energy efficiency in projects and purchases.
- Energy data collection plan: define what to measure, how often and with what accuracy.
- Evaluation and improvement: monitor indicators, compare them with the baseline, carry out internal audits and management reviews and demonstrate improved energy performance.
How the certification process works
- Gap analysis: the organization assesses its available consumption data, existing metering and management practices.
- Implementation: the energy review, EnPIs and EnB, action plans and operational controls are put in place, followed by an internal audit and management review.
- Stage 1 audit: the certification body reviews the energy review, indicators, baseline and documentation.
- Stage 2 audit: auditors check in practice the control of significant energy uses, metering, records and the consistency of the results presented.
- Certification and surveillance: once nonconformities are addressed and improved energy performance has been demonstrated, the certificate is issued. In later audits, the organization must keep demonstrating that improvement.
Frequently asked questions
Does ISO 50001 certification require a minimum reduction in consumption?
There is no fixed percentage. The organization sets its own targets, but it must show, with data, that its energy performance has improved over time.
What are significant energy uses?
They are uses that account for a substantial share of consumption or offer considerable potential for improvement, such as furnaces, boilers, compressed air, refrigeration or air conditioning. They receive priority attention in the system.
Do I need meters on every piece of equipment?
Not necessarily. Metering must be sufficient to monitor significant energy uses and indicators. The data collection plan defines what is needed and can evolve over time.
Can ISO 50001 be integrated with ISO 14001?
Yes. Both share the same structure, and energy management often complements environmental management, especially for emission reduction targets.
Request a proposal
Want to cut costs and emissions with ISO 50001 certification? Contact DRV to request a proposal. We will learn about your facilities, energy sources and sites and outline the next steps.